CONVENTIONAL
LIGHTNING PROTECTION SYSTEM
Protect Your Property with Conventional Lightning Arresters
ALLTEC is a leader in applying global engineered lightning arresters that reduce risks associated with direct and indirect lightning strikes, as well as diminishing hidden effects of surge events. We focus continuously on innovating new technology, improving solutions, refining product quality, and enhancing customer service. As conventional lightning arresters providers for an energized world, our comprehensive approach to facility protection is used to solve the world's most difficult lightning, grounding, and power quality problems. ALLTEC has the knowledge, experience, and products to provide the optimal protection solution.
All of our products are made from high-quality materials with strict quality assurance procedures to ensure that all of our parts will perform to specification and provide many years of worry-free service. The products includes are:
1) Air Terminal and Terminal Bases
2) Down Conductor Holder at roof terrace, and down conductor holder at wall surface And parapet,
3) Clamps, Connectors, Fasteners, and Hardware
4) Saddle Rod Brackets & Coupling Metric System
SEND ENQUIRY
STANDARDS & CODE SPECIFICATION
COMPLIANCE
ALLTEC is accredited and certified by numerous standards authorities. As an expert in the latest approved standards and code specifications for grounding and lightning protection systems, ALLTEC is a sought-after member of standards committees. When your company enlists our complete turn-key services, you ensure compliance with these organizations.
NBC - 2016
IEEE 80 & 81
UL 96A & UL 1449
NFPA 780
LPI 780
API 2003 & API 545
IEC 62305 & IEC 61643
What Is a Conventional Lightning Arrester?
A conventional lightning arrester, also known as a lightning rod, lightning protector, or Franklin rod. It is a device designed to protect structures from the damaging effects of lightning strikes.
The primary purpose of a lightning arrester is to provide a low-resistance path for the lightning current to follow, directing it safely to the ground and away from the protected structure or equipment.
Why Choose GPS India's Conventional Lightning Arresters?
Here are just a few reasons why you should consider GPS India's lightning arresters:
1. High-Quality Materials: GPS India uses only the highest-quality materials in their lightning arresters, ensuring that they are durable and long-lasting.
2. Rigorous Testing: GPS India's lightning arresters are rigorously tested to ensure that they meet the highest standards of performance and reliability.
3. Experienced Manufacturer: GPS India has years of experience in manufacturing lightning protection equipment, making them experts in the field.
4. Competitive Pricing: GPS India's lightning arresters are competitively priced, making them an excellent value for the money.
Benefits of Using Conventional Lightning Arresters
Using conventional copper lightning arresters has several benefits, including:
1. Protecting Your Property: Lightning arresters protect your property from lightning strikes, preventing damage to your electrical systems and other infrastructure.
2. Safety: Lightning arresters improve the safety of your property by preventing electrical fires and other hazards caused by lightning strikes.
3. Lower Insurance Costs: Installing lightning protection systems can lower your insurance premiums by reducing the risk of property damage from lightning strikes.
4. Peace of Mind: Knowing that your property is protected from lightning strikes can give you peace of mind and reduce your stress levels.
5. Lower Maintenance Costs: This lightning arresters require minimal maintenance, reducing the overall cost of protecting your property from lightning damage.
Genius Protection System Private Limited offers conventional lightning arresters that meet all of these criteria, making them an excellent choice for property owners looking for reliable and effective lightning protection.
Frequently Asked Questions
Que. What is a conventional lightning protection?
Ans. A conventional lightning protection is a device that provides a path for lightning to follow to the ground, protecting electrical equipment from damage.
Que. Why should I choose GPS India's lightning arresters?
Ans. GPS India's lightning arresters are made from high-quality materials, rigorously tested, and competitively priced, making them an excellent value for the money.
Que. Can lightning arresters prevent lightning strikes?
Ans. No, lightning arresters cannot prevent lightning strikes. However, they can divert the lightning's electrical energy away from your property, protecting your electrical systems and other infrastructure.
Que. How long do lightning arresters last?
Ans. Lightning arresters can last for many years with proper maintenance and care.
Que. Can I install lightning arresters myself?
Ans. No, lightning arresters should be installed by a qualified professional to ensure that they are installed correctly and function properly.
Que. Can lightning arresters protect my entire property?
Ans. Lightning arresters can protect specific areas of your property, such as electrical systems and other infrastructure. To protect your entire property, you may need to install multiple lightning arresters.
Conclusion
Protecting your property from lightning strikes is essential to prevent damage to your electrical systems and other infrastructure. Conventional lightning arresters are an effective and affordable way to protect your property from lightning damage. GPS India's high-quality lightning arresters provide reliable and long-lasting performance, making them an excellent choice for property owners looking to protect their assets.
With Genius Protection System Private Limited conventional lightning arresters, you can have peace of mind knowing that your property is protected from lightning strikes. Contact GPS India today to learn more about their lightning protection equipment and how they can help you protect your property from lightning damage.
ALLTEC EXPERTIES:
1. Designing of Lightning protection system as per NBC-2016
2. Structure Lightning Protection.
3. Lightning Risk assessment.
4. Designing of Lightning protection system as per NBC-2016
5. Earthing design and Termination.
6. Site Surveys and analysis
7. Soil Resistivity tests and surveys.
Table as per NBC-2016 Clause 11.5.1.2: Maximum values of mesh size and protection angle corresponding to class of LPS
Sl No | Class of LPS | Mesh Size (m) | Rolling Sphere | Protection angle with respect to height (m) |
---|
Radius(m) | ||||||||
---|---|---|---|---|---|---|---|---|
10m | 20m | 30m | 45m | 60m | ||||
1 | 5x5 | 20 | 45 | 23 | --can not be used-- | |||
II | 10x10 | 30 | 54 | 38 | 23 | --can not be used-- | ||
III | 15x15 | 45 | 62 | 48 | 36 | 3 | --can not be used-- | |
IV | 20x20 | 60 | 65 | 54 | 45 | 34 | 23 |
Vertical Air Terminals
Alltec Air Terminals meet or exceed the material specifications and requirements of Underwriters Laboratories, Inc., (UL®) and the Lightning Protection Institute (LPI). Air Terminal (1148A) 1/2 - 48" UNC Threads- Standard
Part No | Description | Weight |
---|---|---|
1112A | Air Terminal, Aluminium,1/2" dia., 12" | 0.10 kg |
1116A | Air Terminal, Aluminium,1/2" dia., 16" | 0.14 kg |
1118A | Air Terminal, Aluminium,1/2" dia., 18" | 0.16 kg |
1124A | Air Terminal, Aluminium,1/2" dia., 24" | 0.20 kg |
1136A | Air Terminal, Aluminium,1/2" dia., 36" | 0.30 kg |
1148A | Air Terminal, Aluminium,1/2" dia., 48" | 0.40 kg |
Air Terminals Base
Used for mounting on a flat surface or against the inside of vertical walls. Can be mounted with Adhesive or fasteners. Part Number Description Weigh
Part No | Description | Weight |
---|---|---|
2015A |
Base,Aluminium,1/2"-13 Threaded I.D.,Flat surface, for air Terminal |
119.1g |
Cross Connector: cross connector for 8mm Aluminum conductor
Part No | Description | Weight |
---|---|---|
3231A |
Clamp,Aluminium,for Cross Runs, Mechanical |
101.9 g |
Universal Connector: T/L/Straight connector for 8mm Aluminum conductor
Part No | Description | Weight |
---|---|---|
3232A |
Clamp,Aluminium,for Straight/U Runs, Mechanical |
88.0g |
Downn Conductor: 8mm Aluminum down conductor
Part No | Description | Weight |
---|---|---|
4321A |
8mm Aluminum Conductor | 142g/m |
Conductor Holder: Poly plastic Conductor holder for Terrace surface
Part No | Description | Weight |
---|---|---|
5321A |
Conductor Holder for Terrace Flat Surface |
1.2kg |
Conductor Holder: Conductor holder for Wall parapet surface
Part No | Description | Weight |
---|---|---|
5322A |
Conductor Holder for wall Parapet | 50g |
Conductor Holder: Metal Conductor holder for metal roof/wall
Part No | Description | Weight |
---|---|---|
5323A |
Metal Conductor holder for metal roof/wall |
26.9g |
Expansion Piece: Joint for expansion and contraction of conductor
Part No | Description | Weight |
---|---|---|
6321A |
Aluminum, compensate the expansion and contraction of conductor |
68.5g |
Test Link Joint: Test Link Joint: Connects round and flat conductor
Part No | Description | Weight |
---|---|---|
7321A |
Aluminum link ,connects round and flat conductor |
87.5g |
Folding Conductor Holder: Metal Conductor holder for metal roof
Part No | Description | Weight |
---|---|---|
8321A |
Metal Conductor holder for metal roof/wall |
97.4g |
Aluminum Ferrule : Aluminum ferrule to connect 8 mm Al Conductor
Part No | Description | Weight |
---|---|---|
9321A |
Aluminum ferrule to connect 8 mm Al Conductor |
23.2g |
If You Need Any Solution. We Are Available For You !